Biometer Laboratory Oscillating Equipment Vertical Large Capacity Shaking Incubator
Product Features
■Double deck shaking plate, large working space design;
■Double hollow toughened glass doors, easy to observe the internal situation; The side is equipped with test holes, convenient to test and meet the sample’s demand for oxygen;
■ Equipped with light and UV sterilization lamp, easy to observe and sterilization
■ Imported non-fluorine refrigeration compressor, unique refrigeration working mode design, to ensure that the compressor will not be closed due to its own overheating, so as to achieve high quality temperature control effect;
■ Centrifugal circulating air duct, forcing the air flow in the working room, more uniform temperature;
■ High pressure
Technical Parameters
Type |
ZHPL-500 |
ZQPL-500 |
ZHPL-500A |
ZQPL-500A |
Standard control system |
LCD |
|||
Shaking frequency |
10-300rpm |
|||
Shaking frequency accuracy |
±1rpm |
|||
Vibration Range |
26mm |
35mm |
||
Temp Range |
+5 ~65°C |
4~65C |
+5 ~65°℃ |
4~65C |
Temperature Resolution |
±0.1℃ |
|||
Temperature uniformity |
±1 (37°C) |
|||
Temperature Fluctuation |
±0.3°C (37C) |
|||
Control mode |
P.I.D microcomputer intelligent control |
|||
Shaking plate size (mm) |
830×500mm/2PCS |
|||
Single layer large volume |
100m×77 250mlx45 500ml×37 1000mlx182000mlx13 |
|||
Single layer standard volume |
100m×45 250ml×35 500ml×24 1000mlx12 2000ml×8 |
|||
Factory standard specifications |
2 Layers (lower level fixed fixture 1000mlx12, upper level fixed fixture 500mlx24) |
|||
Timing range |
|
|||
Power(kw) |
1.8 |
2.1 |
1.9 |
2.2 |
Power Supply |
AC220±10%50~60Hz |
|||
Dimension mm |
1060*800*1470 |
|||
Package size mm |
1190*895*1640 |
|||
NW(kg) |
280 |
300 |
420 |
440 |
Note:
1. Performance parameter testing under no-load conditions: ambient temperature 20° c, humidity 50%RH
2. Working ambient temperature: 5-25ºC
3. In order to give full play to the best use of the equipment, all products at the factory in accordance with the standard fixture configuration capacity configuration shall prevail.
Optional Configuration
Fittings | Functions |
True color touch screen program temperature control system | 1,Adopted 16 byte 4.3-inch true color touch screen computer control system, resistive touch screen, high touch accuracy, stability and reliability; 2,Control mode, setting mode and program mode selectable; Programmable program five kinds of modes, each mode can be set to 30 control steps, each step can be set from 0 to 999 hours 59 minutes; 3,You can draw real-time curve and the historical curve, and print screenshots; save up to 1 year historical data, and can be exported U disk backup or printout; choose to data or curve mode, real-time print measurement data; 4,Permission login system to ensure the operation of security, the timing of all control functions locked; 5,The standard configuration of illumination, and sterilization function; 6,optional buy our company matching computer software, real-time monitoring equipment through Ethernet |
Micro printer | Print control data according to the need |
485 interface remote control system | Can be based on the needs of the work of remote control and data analysis, export |
USB interface | According to the needs of the work, export of experimental data, does data analysis |